Display: HD LCD color display
Dimensions: 54X80X64MM
Display color: red orange yellow white green blue
Protruding size: 45X16MM
Installation method: rail type
Measurement accuracy: 1%±2 words
Function test: AC voltage, current, power, frequency, electric energy, power factor
Measuring speed: 2 times per second
User Guide:D52-2066 guide rail type digital display multi-function meter simultaneously displays 6 parameters such as AC voltage, AC current, active power, power factor, frequency and electric energy on the instrument. The meter uses a color full-view high-definition LCD display to display the measurement results.
Technical Indicators:
1.Accuracy: 1%±2 words
2.Measuring Range:
AC voltage: AC 80.0-300.0V or AC 200.0-450.0V
AC Current: AC 0-100.0A, the current resolution is 0.01A.
Frequency: 45.0Hz – 65.0Hz
Power Factor: 0.00-1.00PF
Electric Power: 0-450000W, the electric power resolution is 0.1W when measure electric power between 0-9999.9W, otherwise the electric power resolution is 1W.
Electric Energy: 0-99999kwh, the display of electric energy resolution is 0.01kwh when measure electric engery between 0-999.99kwh, the display of electric energy resolution is 0.1kwh when measure electric engery between 1000.0-9999.9kwh and the display of electric energy resolution is 1kwh when measure electric engery larger than 9999.9kwh
3. Measuring speed: about 2 times per second
4. Dimensions: 54mm×80mm×64mm
5. Installation method: rail type
Use and wiring method:
1. Connect the measured voltage to the terminals 1 and 2 on the bottom left of the meter.
2. The built-in transformer is wired according to the wiring diagram in Figure 1, and the wire of the measurement loop is passed through the circular hole under the meter. The direction of the wire penetration can be selected by the user according to the use situation, and it can be penetrated from the circular hole under the meter to the top. , Or come out from the circular hole on the top of the meter, and the different penetration directions will not affect the measurement results.
3. Connections of meter with external current transformer as graph 2. Make the wire through the hole in the meter, and connect the two wires of the secondary transformer to the 3 and 4 terminal.
4. The meter displays the measurement parameters after the power is turned on.
5. When it is necessary to reset the electric energy measurement (when measuring from zero), press and hold the button (RESET) on the right side of the instrument panel for 5 seconds (press and hold for 5 seconds) until the electric energy shows 0, release the button, At this time, the electrical energy is measured from zero. Electric energy has the function of automatically saving data after power failure, that is, when the measurement voltage is disconnected or power failure, the meter will automatically save the current test data, and when the measurement power is reconnected, the meter will continue to accumulate on the previously saved data.
Attention:
The measuring voltage range of this instrument is 200-450V and only suitable for the pure AC 45-65Hz mains power supply, and the measuring range is 40-300V without limitation.
The meter can only use for measure 45-65Hz AC city electricity.
Wir akzeptieren eine Zahlung per PayPal, Kreditkarte oder Überweisung.
Wir senden Artikel innerhalb von 24 Stunden nach Eingang der Zahlung, und Sie erhalten es in 1-5 Werktagen (außer am Wochenende)
Wir versichern Ihnen, dass wir ein ehrlicher und zuverlässiger Verkäufer bei eBay sind. Jedes Problem, bitte kontaktieren uns zu jeder Zeit, bevor Sie neutrales oder negatives Rückgespräch verlassen, stellen wir Ihnen eine befriedigende Entschließung zur Verfügung.
Wir sind verantwortlicher Verkäufer, wir versuchen unser Bestes, um Ihnen mit vollkommenen Produkten zur Verfügung zu stellen und Ihnen vollkommene Einkaufserfahrung zu geben. Irgendwelche Fragen, zu jeder Zeit mit uns in Verbindung zu kontaktieren , lösen wir es mit einer zufriedenen Entschließung.
|